Units: D, d, t in inches; As in in²; F in lb (klb = 1,000 lb); L in ft; E = 30,000,000 psi for steel. Metric: mm, mm², N (kN), m, MPa; E = 206,843 MPa. Conversions are exact constants (the units conversion rules). Calculators work in US units internally and convert at the screen.
F1 Pipe-body area.
As = π/4 · (D² − d²). Metric: As(mm²) = As(in²) × 645.16.
- 5-1/2” 17# N-80 (D 5.500, d 4.892): 30.250 − 23.931664 = 6.318336; × 0.785398 = 4.9624 in² (3,201.5 mm²).
- 7” 23# J-55 (D 7.000, d 6.366): 49.000 − 40.525956 = 8.474044 → 6.6555 in².
- 9-5/8” 40# N-80 (D 9.625, d 8.835): 92.640625 − 78.057225 = 14.583400 → 11.4538 in².
F2 Wall and plain-end weight.
t = (D − d)/2. w_pe = 10.68 · (D − t) · t lb/ft. Where 10.68 comes from: steel at 0.2833 lb/in³ × 12 in/ft × π. (The table formula uses 10.69; the 0.1% gap is inside the check’s tolerance.) Metric: w_pe(kg/m) = 0.024635 · (D − t) · t with mm.
- 5-1/2” 17# N-80: t = (5.500 − 4.892)/2 = 0.304 in; w_pe = 10.68 × 5.196 × 0.304 = 16.87 lb/ft (nominal 17.00, couplings make up the rest).
F3 Body yield.
P_y = As · Y. 5-1/2” 17# N-80: 4.9624 × 80,000 = 396,993 lb (sheet 397 klb). 9-5/8” 40# N-80: 11.4538 × 80,000 = 916,302 lb (sheet 916 klb). Which figure the tools use: for a table row, P_y is always the row’s body_yield_lb, the sheet value after corrections (the body-yield check holds it within 1% of As · Y); As · Y is used only for “Enter your own” pipe. F9, F10, the configurator and the downloads all use the sheet value (397,000; 916,000; 366,000), and the jack-check and build-sheet examples are figured that way.
F4 Stretch.
Hooke’s law for a bar: strain = stress / E, so ΔL/L = F/(As·E). With L in feet and ΔL in inches, multiply by 12: ΔL (in) = F · L · 12 / (E · As). Metric: ΔL (mm) = F (N) · L (mm) / (E (MPa) · As (mm²)).
- Worked example: 5-1/2” 17#, F = 50,000 lb, L = 6,000 ft: 50,000 × 6,000 × 12 = 3.6 × 10⁹; E · As = 30,000,000 × 4.962409 = 1.488723 × 10⁸; ΔL = 24.18 in.
- Same in metric: F = 222.411 kN, L = 1,828.8 m, As = 3,201.55 mm², E = 206,842.7 MPa → ΔL = 614.2 mm (= 24.18 × 25.4).
F5 Stretch constant.
Put F in klb and L in thousands of feet: ΔL = (1,000 F_k)(1,000 L_k)(12)/(30,000,000 · As) = F_k · L_k · 0.4/As. So SC = 0.4 / As (inches of stretch per 1,000 lb per 1,000 ft) and ΔL = F_k · L_k · SC.
- 5-1/2” 17#: SC = 0.4 / 4.962409 = 0.08061. Check: 50 × 6 × 0.080606 = 24.18 in, same as F4.
F6 Free point.
Solve F4 for L: L = ΔL · E · As / (12 · F). With F in klb (F = 1,000 F_k): L = ΔL · 30,000,000 · As / (12,000 · F_k) = ΔL · (2,500 · As) / F_k. So the free-point constant FPC = 2,500 · As, and free point (ft) = stretch (in) × FPC / pull (klb). In the field the stretch is read between two pulls (the first takes out slack), so F_k is the difference between the two pulls and ΔL the difference in pipe movement. The answer is the length of free pipe; friction makes the true free point deeper, never shallower. Metric: L (m) = ΔL (mm) · E (MPa) · As (mm²) / (F (N) · 1,000).
- 7” 23# J-55: FPC = 2,500 × 6.655499 = 16,639. Stretch 20 in between pulls 40,000 lb apart: 20 × 16,638.75 / 40 = 8,319 ft.
- Round trip on F4: 24.1818 in × 12,406.02 / 50 = 6,000 ft (FPC for 5-1/2” 17# = 12,406).
F7 Buoyancy.
Steel weighs 65.5 lb/gal (7,849 kg/m³). A string full of and standing in fluid of weight MW loses that share: BF = 1 − MW / 65.5. Metric: BF = 1 − ρ (kg/m³) / 7,849. Buoyed weight W_b = w · L · BF (w nominal lb/ft).
- 10.0 ppg: BF = 1 − 10/65.5 = 0.8473. 9-5/8” 40#, 3,000 ft: 40 × 3,000 = 120,000 lb in air; × 0.847328 = 101,679 lb.
F8 Pull needed.
Pull needed = buoyed weight of the pipe being lifted (from surface to the free point or cut) + the extra pull the customer expects to break it free. The user can type their own figure instead.
- 5-1/2” 17#, free point 6,000 ft, 9.0 ppg: BF = 1 − 9/65.5 = 0.862595; 17 × 6,000 × 0.862595 = 87,985 lb; + 100,000 lb extra = 187,985 lb.
F9 Max pull on the string.
Max safe pull = lesser of pipe-body yield (the row’s sheet value, F3) and the joint strength of the chosen connection, divided by the design factor: P_allow = min(P_y, P_joint) / DF (default DF 1.25 = 80%). If the connection is “not sure”, use the lowest joint strength the row lists.
- 9-5/8” 40# N-80, LTC: min(916,000, 737,000) / 1.25 = 589,600 lb. BTC: min(916,000, 979,000) / 1.25 = 732,800 lb.
- 5-1/2” 17# N-80, LTC: min(397,000, 348,000) / 1.25 = 278,400 lb.
F10 Jack check.
Each jack’s relief is capped at its design pull and stops pull at 80% of pipe body yield (both spec sheets). Design pull: TPS-200 400,000 lb (200 short tons, Rev E design values); TPS-400 800,000 lb (400 short tons, Rev B design values, preliminary). Jack pull on this string = min(jack design pull, 0.8 · P_y, P_allow). The check passes when pull needed ≤ that figure. The spec sheets’ proof test (1.25 × design pull, each unit: 250 short tons for the TPS-200, Rev E design values; 500 short tons for the TPS-400, Rev B design values, preliminary) is shown only as a spec line; it is never added to capacity.
- 5-1/2” 17# N-80 LTC on a TPS-200 (Rev E design values): min(400,000, 317,600, 278,400) = 278,400 lb; pull needed 187,985 → passes.
- 9-5/8” 40# N-80 LTC, pull needed 450,000: TPS-200 (Rev E design values) gives min(400,000, 732,800, 589,600) = 400,000 → fails; TPS-400 (Rev B design values, preliminary) gives min(800,000, 732,800, 589,600) = 589,600 lb → passes.
- Fixed slip-crush note, shown with every jack check: “Slips can crush pipe before it reaches its rated pull. Slip-crush capacity for your pipe is set when the jack is engineered for your order; the relief is set to the lower limit.”
F11 Capacity.
One barrel is 9,702 in³ (42 gal × 231 in³). A foot of pipe holds π/4 · d² · 12 in³, so bbl/ft = 12π d² / (4 × 9,702) = d² / 1029.4; ft/bbl = 1029.4 / d². Metal displacement = (D² − d²)/1029.4. Metric: m³/m = bbl/ft × 0.521612.
- 7” 23#: 6.366² = 40.525956; / 1029.4 = 0.03937 bbl/ft (sheet 0.0393685); 25.40 ft/bbl; 0.02054 m³/m.
- 9-5/8” 40#: 78.057225 / 1029.4 = 0.07583 bbl/ft.
Collapse
API TR 5C3 collapse, with Y in psi and r = D/t: A = 2.8762 + 0.10679e-5·Y + 0.21301e-10·Y² − 0.53132e-16·Y³; B = 0.026233 + 0.50609e-6·Y; C = −465.93 + 0.030867·Y − 0.10483e-7·Y² + 0.36989e-13·Y³; with k = B/A and x = 3k/(2 + k): F = 46.95e6 · x³ / (Y · (x − k) · (1 − x)²); G = F·k. Limits: r_yp = (√((A − 2)² + 8(B + C/Y)) + (A − 2)) / (2(B + C/Y)); r_pt = Y(A − F) / (C + Y(B − G)); r_te = (2 + k)/(3k). Collapse = 2Y(r − 1)/r² if r ≤ r_yp; Y(A/r − B) − C if r ≤ r_pt; Y(F/r − G) if r ≤ r_te; else 46.95e6 / (r(r − 1)²). (Checked by the architect: 5-1/2 17# N-80 → 6,285; 7” 23# J-55 → 3,269; 9-5/8 40# N-80 → 3,086; 9-5/8 47# P-110 → 5,296.)
Buoyancy constant
The 65.5 lb/gal constant represents steel density. It gives the fraction of weight retained when pipe is full of and surrounded by the same fluid. The metric density convention is 7,849 kg/m3. The two density conventions are retained as specified in the plan. US units are used internally. No intermediate results are rounded.